| 技术指标 |
| 直流电压 | | *大电压: | 1000V | | 准确度: | Fluke 83 V: ±(0.1%+1) | | | Fluke 87 V: ±(0.05%+1) | | *大分辨率: | Fluke 83 V: 100 µV | | | Fluke 87 V: 10 µV |
|
| 交流电压 | | *大电压: | 1000V | | 准确度: | Fluke 83 V: ±(0.5%+2) | | | Fluke 87 V: ±(0.7%+2) 真有效值 | | 交流带宽 | Fluke 83 V: 5kHz | | | Fluke 87 V: 20kHz* | | | *使用低通滤波器;3db @ 1kHz | | *大分辨率: | 0.1 mV |
|
| 直流电流 | | | (20 A ,30 秒,*大) | | *大电流: | 10A | | 电流准确度: | Fluke 83 V: ±(0.4%+2) | | | Fluke 87 V: ±(0.2%+2) | | *大分辨率: | Fluke 83 V: 0.01 mA | | | Fluke 87 V: 0.01 µA |
|
| 交流电流 | | | (20 A ,30 秒,*大) | | *大电流: | 10A | | 电流准确度: | Fluke 83 V: ±(1.2%+2) | | | Fluke 87 V: ±(1.0%+2) 真有效值 | | *大分辨率: | 0.1 µA |
|
| 电阻 | | *大电阻: | 50 MΩ | | 准确度: | Fluke 83 V: ±(0.4%+1) | | | Fluke 87 V: ±(0.2%+1) | | *大分辨率: | 0.1Ω |
|
| 电容 | | *大电容 | 9,999 µF | | 准确度 | ±(1%+2) | | *大分辨率 | 0.01 nF |
|
| 频率 | | *大频率 | 200 kHz | | 准确度 | ±(0.005%+1) | | *大分辨率 | 0.01 Hz |
|
| 占空比 | | *大占空比 | | | 准确度 | ±(0.2% /khz +0.1%) | | *大分辨率 | |
|
| 温度测量 | | Fluke 83 V, 87 V/E: | -200.0°C - 1090°C | | | -328.0°F - 1994.0°F | | | 不包括探头 |
|
| 80 BK 温度探头 | | | -40.0°C - 260°C | | | -40.0°F - 500°F, 2.2°C 或 2%,取较大值 |
|
| 电导率 | | *大电导率 | 60.00 nS | | 准确度 | ±(1.0%+10) | | *大分辨率 | 0.01 nS |
|
| 二极管 | | | 量程 3 V | | 分辨率 | 1 mV | | 准确度: | ± (2 % + 1) |
|
| 占空比量程 | | 准确度: | ± (0.2% /kHz + 0.1 %)之内 |
|