OPERATION MODE |
| Independent | (0~60V/0~3A) x 2, (5V/3A Max.) x 1 |
| Series | 120V 3A |
| Parallel | 60V 6A |
5V FIXED OUTPUT |
| Line Regulation | < 5mV |
| Load Regulation | < 10mV |
| Ripple & Noise | < 2mVrms |
| Voltage Accuracy | 5V±0.25V |
| Output Current | 3A |
TRACKING OPERATION |
| Tracking Error | < 0.5% + 10mV of the master |
| Series Regulation | < 300mV |
CONSTANT VOLTAGE OPERATION |
| Line Regulation | < 0.01%+3mV |
| Load Regulation | <0.01% + 3mV (rating current <3A) < 0.02% + 5mV (rating current <10A) |
| Ripple & Noise | < 1mVrms 5Hz ~ 1MHz |
| Current Output | < 100μS ( 50% load change, minimum load 0.5A ) |
CONSTANT CURRENT OPERATION |
| Line Regulation | < 0.2% + 3mA |
| Load Regulation | < 0.2% + 3mA |
| Ripple & Noise | < 3mArms |
METER |
| Type | 3 1/2 digit 0.5" LED display |
| Accuracy | ±( 0.5% of rdg + 2 digits ) |
INSULATION |
| Chassis and Terminal | 20MΩ or above (DC 500V) |
| Chassis and AC Cord | 30MΩ or above (DC 500V) |
| POWER SOURCE | |
| | AC 100V/120V/220V/240V ±10%, 50/60Hz |
ACCESSORIES |
| | User manual x 1 Power cord x 1 Test lead GTL-104 x 2 (<10A), GTL-105 x 1(<3A) European test lead GTL-204 x 2(<10A), GTL-203 x 1(<3A) |
| DIMENSIONS & WEIGHT | |
| | 255(W) x 145(H) x 346(D)mm Approx. 18.5kg |